Korund-Classic

Corundum-Classic is a universal heat-resistant and weather-resistant coating that is actively used for thermal insulation work indoors. Can be used for thermal protection of external coatings of pipelines, chimneys, steam lines, enclosing structures and shut-off valves.

Image

Korund-Liquid roofing

Corundum-Classic is a universal heat-resistant and weather-resistant coating that is actively used for thermal insulation work indoors. Can be used for thermal protection of external coatings of pipelines, chimneys, steam lines, enclosing structures and shut-off valves.

Image

Korund-Classic

Corundum-Classic is a universal heat-resistant and weather-resistant coating that is actively used for thermal insulation work indoors. Can be used for thermal protection of external coatings of pipelines, chimneys, steam lines, enclosing structures and shut-off valves.

Image

Korund-Liquid roofing

Corundum-Classic is a universal heat-resistant and weather-resistant coating that is actively used for thermal insulation work indoors. Can be used for thermal protection of external coatings of pipelines, chimneys, steam lines, enclosing structures and shut-off valves.

FAQ

Is it necessary to do a thermal engineering calculation?

Preferably. Thermal engineering calculation allows you to determine the estimated thickness of the Korundum thermal insulation coating required to complete the task. However, despite the fact that the thermal engineering calculation is performed according to the methods recommended by the Code of Rules, it is not a design solution. If you need a project or a corresponding section of project documentation, you must contact specialized organizations.

By how many degrees does the temperature on the surface decrease when applying 1 layer of thermal insulation coating Corundum?

It depends on specific conditions - surface temperature, ambient temperature.

What paint and varnish materials can be applied over the heat-insulating coating Corundum?

You can apply plaster, any high-quality acrylic paints, wallpaper, etc.

Why is it recommended to apply the thermal insulation coating Corundum as a finishing layer?

Thermal insulation coating Corundum has a low heat transfer coefficient, much lower than that of finishing materials. Therefore, the use of Corundum as a finishing coating makes it possible to use the unique properties of the material as efficiently as possible.

Is 24 hour drying required between coats?

Application of the thermal insulation coating Corundum Classic should be carried out in accordance with the Application Instructions...
According to instructions:
The time for complete drying of one layer of coating with a thickness of 0.4-0.5 mm is at least 24 hours at an ambient temperature above +20 ° C and humidity not higher than 80% throughout the entire drying time - 24 hours. In case of changes in environmental conditions (lower temperature, higher humidity) drying time must be increased. The next layer can be applied only after the previous layer has completely dried.
The requirement to apply the coating in layers of no more than 0.5 mm is due to the curing mechanism of the coating. After applying the composition to the surface, during the curing of the coating, diffusion to the surface of the film and evaporation of solvents into the environment occurs. When a composition layer of more than 0.5 mm is applied at a time, not all of the solvent has time to evaporate from the cured coating. Since the thermal conductivity coefficient of the solvent is several times greater than the thermal conductivity coefficient of the Corundum coating, there is a sharp decrease in the effectiveness of thermal insulation.
For the same reason, it is necessary to comply with the requirement for interlayer drying time.
The requirement to apply a single layer with a thickness of no more than 0.5 mm and a drying time of 24 hours is critical; if it is not met, the thermal insulation coating Corundum ceases to perform the functions of thermal insulation.

Is it possible to apply decorative plaster or facing tiles on top of the Corundum heat-insulating coating?

Possibly after the material has completely dried, but not earlier than 36 hours from the moment of the finishing coat.

What pastes can be used to tint the thermal insulation coating Corundum?

It is possible to tint the material yourself using any high-quality pigment paste for water-dispersion paints.

Why is the thermal insulation coating Corundum Anticor recommended to be applied only as the first layer? Is it necessary to apply the Corundum Classic or Corundum Facade modification on top of it?

Корунд Антикор исходя из своего названия предназначен для предотвращения развития процессов коррозии на поверхности металла. Нанесение 1 единичного слоя этой модификации позволяет блокировать распространение ржавчины. Корунд Антикор рекомендуется наносить в качестве только первого слоя, поскольку применение его в последующих слоях экономически нецелесообразно. На поверхность Корунд Антикор возможно наносить и Корунд Классик и Корунд Фасад.

After opening the bucket, how quickly should the Corundum thermal insulation coating be used?

After opening the bucket, it is necessary to use the composition as quickly as possible, however, if necessary, you can hermetically seal the bucket with the material and use it later. The issue of preserving the material after opening the bucket depends on the specific storage conditions. The material is preserved quite well when stored in a hermetically sealed container. However, if the material has “dried out”, it will most likely not be possible to use it in the future.

How does the Corundum NG modification differ from Fire Protection?

Fire retardant coatings are used to increase the durability of metal structures in case of fire. For example, Corund-Fire Protection allows you to prevent the loss of load-bearing capacity of metal structures in case of fire for up to 1 hour. In the event of a fire, this time should be enough for the appropriate services to arrive to eliminate the fire and, first of all, to evacuate people. Corundum NG is a heat-insulating material that destructs at high temperatures (fire) without supporting combustion.

Application form

Dear Customer! Please, leave your contact details and our specialist will contact you.

I consent to the processing of personal data in accordance with the privacy policy.

Image

Stay up to date news and promotions

2024. FULLEREN. Website by PS. All rights reserved.